okami.mom/strata

git clone https://git.nkp.pet/okami.mom/strata

Niko1221merge f-split into f-split-s6326e39118

main
6.7 KiB78 linesraw

Closing: what ends the engine, and when

The rule: a Strata server, and the engine it started, end when whatever started them ends, however that ends. There is a clean path (the engine finishes or cancels its request, frees its memory, exits) and, behind it, a guarantee that does not need any Strata code to run (a crash, kill -9, the console closed, logoff). The clean path is tried first; if the engine does not exit in time it is killed. After either, the port and the GPU memory are free.

The two ways to run an engine

Started byEnds withStop it with
Foregroundstrata serve --profile NAME (or python serve/server.py)the terminal / the commandCtrl+C, closing the window, kill
Background service (on purpose)strata runtime start --profile NAMEnothing: it keeps serving after the terminal closesstrata runtime stop --profile NAME
The Desktop app's enginesthe app (profiles app-1, app-2, ...)the app: its window, its process, its hostclosing the app, or the app's unload

The background service is a deliberate choice and stays one: runtime start starts an owner host that is not tied to the terminal that ran it. It is documented in strata runtime --help. If you want it to follow a process, --die-with-pid PID ties it to that process (the app does this for every engine it starts). Engines the Terminal starts are never stopped by the app, and the app's app-N engines are not stopped by the Terminal unless you run runtime stop --profile app-1.

What each way of ending does

Clean path first: the server gets the stop request, drains or cancels its current requests (--shutdown-timeout, 30 s in the Terminal, 15 s for the app's engines), writes STOP then QUIT to the engine (a request still running is cancelled at its next step), waits 20 s, terminates, waits 5 s, kills. The engine and the image encoder run in their own process group (a new process group on Windows) so that a terminal's Ctrl+C / hangup reaches the server only, and the server stops the engine in that order instead of the engine dying under a request.

EventWindowsLinuxmacOS
Ctrl+C in the terminalserver handles it, clean stopsame (SIGINT)same
kill (SIGTERM), docker stop, systemd stopn/aclean stopclean stop
Terminal window closed / ssh droppedconsole close event: clean stop (the system allows ~5 s); the job object ends anything leftSIGHUP: clean stop. Not when started with nohup (that asks to outlive the terminal)same
Ctrl+Breakclean stopn/an/a
Logoff, shutdownconsole logoff/shutdown event, then the job objectSIGHUP/SIGTERM from the session managersame
The server is killed (taskkill /F, kill -9, crash)the engine is in a kill-on-close job object owned by the server: it ends at oncePR_SET_PDEATHSIG = SIGKILL, set before the engine starts, from one long-lived thread (the signal is tied to the thread that forks, not the process)a watcher process holds a pipe to the server; when the server dies the watcher ends the engine after checking its PID and start time
The owner host (runtime start) is killedthe job object holding the server tree ends itthe server's owner pipe closes: it gets SIGTERM and a clean stop, SIGKILL after the grace periodsame
The app is closed (window X, normal exit)the host stops the app's engines through Control (drain, end), then exits; 60 s deadline, then the job objectsame, no job object: the owners follow the hostsame
The app is killed, crashes, logoffthe job object around the app ends the host, Control, the owner host, the server and the enginethe host sees its parent gone within a second, stops the engines cleanly; each owner follows the host's PID (--die-with-pid)same
The app's host crasheseach owner sees the host's PID gone (about a second) and stops its engine, drainedsamesame

strata_control/procs.py is the identity rule behind every "is this still the process I started": PID and start time and command line, checked again at the moment of each signal. A PID alone is never signalled.

Leftovers, and how they are found

Every engine, image encoder and server Strata starts writes a small private record (<state>/procs/<pid>.json: PID, start time, command line, and the same for its parent). Records are removed when the process ends. If everything dies anyway and a process is left, the next of these ends it, after the check above:

  • the next engine start (strata serve, runtime start, the app loading a model), for any leftover on the machine whose parent is gone;
  • strata runtime stop --profile NAME when the owner host is lost (it ends the recorded server and engine and clears the private state, instead of failing with "runtime control is unavailable");
  • strata runtime cleanup [--profile NAME], on demand (--json for scripts); a running instance is never touched;
  • the app host, once at start.

Engines older Strata versions left behind wrote no record. At an engine start, an orphan of exactly the executable about to be started (--serve on its command line, no live parent: its server is gone) is ended the same way; another installation's engine, or any process whose parent is alive, is not. Set STRATA_KEEP_LEFTOVERS=1 to turn both checks off.

One app, one or several engines

The desktop app is a single instance (the Tauri single-instance plugin): launching it again focuses the window that is open and starts nothing, so two apps never fight over the app-N slots. One app can run several engines (for example one per GPU): every model the app loads gets its own profile app-1, app-2, ... under Control, each with its own owner, server and engine, and each is stopped with the app. Which GPU a model uses is the model's run config (gpu); the app starts one engine per loaded model. Choosing the card per model needs a control in the Models/Serving screens; there is none today (see the notes of the f-split-life stream for what it would need).

Proving it

tests/terminal/lifecycle_matrix.py runs every case above with a fake engine package, or a real engine (--config RUN.json --components DIR --vram), and asserts after each: no process of the tree is left, the port is free, the runtime lease can be taken, the GPU memory returned. tests/terminal/test_lifecycle_matrix.py is the pytest wrapper (the cases that need a console window run with STRATA_MATRIX_CONSOLE=1). apps/desktop/scripts/app-close-matrix.py drives the installed Windows app (normal close, window X, killed app, host crash, second launch, two engines). tests/terminal/ssh_disconnect.py drops a real ssh session on a Linux box.

1# Closing: what ends the engine, and when
2
3The rule: **a Strata server, and the engine it started, end when whatever started them ends, however that ends.** There is a
4clean path (the engine finishes or cancels its request, frees its memory, exits) and, behind it, a guarantee that does not
5need any Strata code to run (a crash, `kill -9`, the console closed, logoff). The clean path is tried first; if the engine
6does not exit in time it is killed. After either, the port and the GPU memory are free.
7
8## The two ways to run an engine
9
10| | Started by | Ends with | Stop it with |
11|---|---|---|---|
12| **Foreground** | `strata serve --profile NAME` (or `python serve/server.py`) | the terminal / the command | Ctrl+C, closing the window, `kill` |
13| **Background service** (on purpose) | `strata runtime start --profile NAME` | nothing: it keeps serving after the terminal closes | `strata runtime stop --profile NAME` |
14| **The Desktop app's engines** | the app (profiles `app-1`, `app-2`, ...) | the app: its window, its process, its host | closing the app, or the app's unload |
15
16The background service is a deliberate choice and stays one: `runtime start` starts an owner host that is not tied to the
17terminal that ran it. It is documented in `strata runtime --help`. If you want it to follow a process, `--die-with-pid PID`
18ties it to that process (the app does this for every engine it starts). Engines the Terminal starts are never stopped by the
19app, and the app's `app-N` engines are not stopped by the Terminal unless you run `runtime stop --profile app-1`.
20
21## What each way of ending does
22
23Clean path first: the server gets the stop request, drains or cancels its current requests (`--shutdown-timeout`, 30 s in the
24Terminal, 15 s for the app's engines), writes `STOP` then `QUIT` to the engine (a request still running is cancelled at its
25next step), waits 20 s, terminates, waits 5 s, kills. The engine and the image encoder run in their own process group
26(a new process group on Windows) so that a terminal's Ctrl+C / hangup reaches the server only, and the server stops the engine
27in that order instead of the engine dying under a request.
28
29| Event | Windows | Linux | macOS |
30|---|---|---|---|
31| Ctrl+C in the terminal | server handles it, clean stop | same (SIGINT) | same |
32| `kill` (SIGTERM), `docker stop`, systemd stop | n/a | clean stop | clean stop |
33| Terminal window closed / `ssh` dropped | console close event: clean stop (the system allows ~5 s); the job object ends anything left | SIGHUP: clean stop. Not when started with `nohup` (that asks to outlive the terminal) | same |
34| Ctrl+Break | clean stop | n/a | n/a |
35| Logoff, shutdown | console logoff/shutdown event, then the job object | SIGHUP/SIGTERM from the session manager | same |
36| The server is killed (`taskkill /F`, `kill -9`, crash) | the engine is in a kill-on-close job object owned by the server: it ends at once | `PR_SET_PDEATHSIG` = SIGKILL, set before the engine starts, from one long-lived thread (the signal is tied to the thread that forks, not the process) | a watcher process holds a pipe to the server; when the server dies the watcher ends the engine after checking its PID and start time |
37| The owner host (`runtime start`) is killed | the job object holding the server tree ends it | the server's owner pipe closes: it gets SIGTERM and a clean stop, SIGKILL after the grace period | same |
38| The app is closed (window X, normal exit) | the host stops the app's engines through Control (drain, end), then exits; 60 s deadline, then the job object | same, no job object: the owners follow the host | same |
39| The app is killed, crashes, logoff | the job object around the app ends the host, Control, the owner host, the server and the engine | the host sees its parent gone within a second, stops the engines cleanly; each owner follows the host's PID (`--die-with-pid`) | same |
40| The app's host crashes | each owner sees the host's PID gone (about a second) and stops its engine, drained | same | same |
41
42`strata_control/procs.py` is the identity rule behind every "is this still the process I started": PID **and** start time
43**and** command line, checked again at the moment of each signal. A PID alone is never signalled.
44
45## Leftovers, and how they are found
46
47Every engine, image encoder and server Strata starts writes a small private record (`<state>/procs/<pid>.json`: PID, start
48time, command line, and the same for its parent). Records are removed when the process ends. If everything dies anyway and a
49process is left, the next of these ends it, after the check above:
50
51* the next engine start (`strata serve`, `runtime start`, the app loading a model), for any leftover on the machine whose
52  parent is gone;
53* `strata runtime stop --profile NAME` when the owner host is lost (it ends the recorded server and engine and clears the
54  private state, instead of failing with "runtime control is unavailable");
55* `strata runtime cleanup [--profile NAME]`, on demand (`--json` for scripts); a running instance is never touched;
56* the app host, once at start.
57
58Engines older Strata versions left behind wrote no record. At an engine start, an **orphan of exactly the executable about to
59be started** (`--serve` on its command line, no live parent: its server is gone) is ended the same way; another
60installation's engine, or any process whose parent is alive, is not. Set `STRATA_KEEP_LEFTOVERS=1` to turn both checks off.
61
62## One app, one or several engines
63
64The desktop app is a single instance (the Tauri single-instance plugin): launching it again focuses the window that is open
65and starts nothing, so two apps never fight over the `app-N` slots. One app can run several engines (for example one per GPU):
66every model the app loads gets its own profile `app-1`, `app-2`, ... under Control, each with its own owner, server and engine,
67and each is stopped with the app. Which GPU a model uses is the model's run config (`gpu`); the app starts one engine per
68loaded model. Choosing the card per model needs a control in the Models/Serving screens; there is none today (see the notes of
69the `f-split-life` stream for what it would need).
70
71## Proving it
72
73`tests/terminal/lifecycle_matrix.py` runs every case above with a fake engine package, or a real engine
74(`--config RUN.json --components DIR --vram`), and asserts after each: no process of the tree is left, the port is free, the
75runtime lease can be taken, the GPU memory returned. `tests/terminal/test_lifecycle_matrix.py` is the pytest wrapper (the
76cases that need a console window run with `STRATA_MATRIX_CONSOLE=1`). `apps/desktop/scripts/app-close-matrix.py` drives the
77installed Windows app (normal close, window X, killed app, host crash, second launch, two engines).
78`tests/terminal/ssh_disconnect.py` drops a real ssh session on a Linux box.