"""The default count of CPU expert workers on mock CPUs, and what setup writes about thread counts. The engine's choice is include/strata/kernels/cpu/pool_plan.hpp (tested on its own by the pool_plan_test binary); setup mirrors it so it can warn about a configured count. This test keeps the two in step and checks the mirror on the same mock topologies (8c/16t, 16c/32t, 64c/128t, a 2-socket 128c/256t box) plus the reports behind it: a 256-thread machine started ~256 workers and slowed down. python -m unittest tools.test_pool_plan """ from __future__ import annotations import re import sys import unittest from pathlib import Path from unittest import mock ROOT = Path(__file__).resolve().parents[1] sys.path.insert(0, str(ROOT)) sys.path.insert(0, str(ROOT / "tools")) import setup # noqa: E402 HEADER = ROOT / "include" / "strata" / "kernels" / "cpu" / "pool_plan.hpp" class InStepWithTheEngine(unittest.TestCase): def header_constant(self, name): m = re.search(rf"constexpr int {name}\s*=\s*(\d+);", HEADER.read_text(encoding="utf-8")) self.assertIsNotNone(m, name) return int(m.group(1)) def test_constants(self): self.assertEqual(setup.POOL_WORKERS_CAP, self.header_constant("kPoolWorkersCap")) self.assertEqual(setup.POOL_RESERVE_FROM, self.header_constant("kPoolReserveFrom")) self.assertEqual(setup.POOL_RESERVE, self.header_constant("kPoolReserve")) class DefaultWorkers(unittest.TestCase): def test_mock_topologies(self): cap = setup.POOL_WORKERS_CAP # physical cores, not threads, minus the host thread's core self.assertEqual(setup.plan_pool_workers(16, [8]), 7) # 8c/16t self.assertEqual(setup.plan_pool_workers(12, [6]), 5) # 6c/12t self.assertEqual(setup.plan_pool_workers(32, [16]), 15) # 16c/32t self.assertEqual(setup.plan_pool_workers(128, [64]), cap) # 64c/128t: the cap self.assertEqual(setup.plan_pool_workers(256, [64, 64]), cap) # 2-socket 128c/256t: the cap, never 255 self.assertLess(setup.plan_pool_workers(256, [64, 64]), 128) # two sockets of 20 cores: the host's socket only (bench #674 #707: 17-18 workers beat 35) self.assertEqual(setup.plan_pool_workers(80, [20, 20]), 18) self.assertEqual(setup.plan_pool_workers(48, [6, 18]), 5) self.assertEqual(setup.plan_pool_workers(1, [1]), 1) def test_hybrid(self): self.assertEqual(setup.plan_pool_workers(20, [20], hybrid=(8, 12)), 13) # Core Ultra 7 265 (measured) self.assertEqual(setup.plan_pool_workers(32, [24], hybrid=(8, 16)), 15) # i9-14900KF (#642) self.assertEqual(setup.plan_pool_workers(24, [16], hybrid=(8, 8)), 15) # not more E-cores than P-cores self.assertEqual(setup.hybrid_pool_workers((8, 12)), 13) # setup's own rule agrees def test_unknown_layout_and_quota(self): self.assertLessEqual(setup.plan_pool_workers(256, []), setup.POOL_WORKERS_CAP) self.assertLess(setup.plan_pool_workers(256, None), 255) self.assertEqual(setup.plan_pool_workers(8, None), 7) self.assertEqual(setup.plan_pool_workers(128, [64], quota=4.0), 3) # a container limit of 4 CPUs def test_never_writes_a_big_count(self): # the hybrid rule (P-cores + half the E-cores) is capped like every other count with mock.patch.object(setup, "cpu_cores", return_value=(8, 120)): args = setup.recommend_pool_workers(["--spec", "4"]) n = int(args[args.index("--pool-workers") + 1]) self.assertLessEqual(n, setup.POOL_WORKERS_CAP) with mock.patch.object(setup, "cpu_cores", return_value=(8, 16)): # an ordinary hybrid: the usual 15 args = setup.recommend_pool_workers([]) self.assertEqual(args, ["--pool-workers", "15"]) with mock.patch.object(setup, "cpu_cores", return_value=None): # not hybrid: nothing written self.assertEqual(setup.recommend_pool_workers(["--spec", "4"]), ["--spec", "4"]) # a count that is already there is never changed with mock.patch.object(setup, "cpu_cores", return_value=(8, 120)): self.assertEqual(setup.recommend_pool_workers(["--pool-workers", "200"]), ["--pool-workers", "200"]) def test_vision_threads(self): self.assertEqual(setup.vision_threads(16), 8) self.assertEqual(setup.vision_threads(256), setup.VISION_THREADS_CAP) self.assertEqual(setup.vision_threads(1), 1) class ConfiguredCountWarns(unittest.TestCase): big = (256, [64, 64]) def test_warns_above_the_plan_and_keeps_the_count(self): args = ["--pool-workers", "255"] note = setup.pool_workers_note(args, self.big) self.assertEqual(len(note), 1) self.assertIn("--pool-workers %d" % setup.plan_pool_workers(*self.big), note[0]) self.assertIn("stays as you set it", note[0]) self.assertEqual(args, ["--pool-workers", "255"]) # nothing rewritten def test_quiet_when_fine(self): self.assertEqual(setup.pool_workers_note([], self.big), []) self.assertEqual(setup.pool_workers_note(["--pool-workers", "8"], self.big), []) self.assertEqual(setup.pool_workers_note(["--pool-workers", str(setup.plan_pool_workers(*self.big))], self.big), []) self.assertEqual(setup.pool_workers_note(["--pool-workers"], self.big), []) self.assertEqual(setup.pool_workers_note(["--pool-workers", "x"], self.big), []) def test_reasons(self): self.assertIn("CPU threads", setup.pool_workers_note(["--pool-workers", "300"], self.big)[0]) self.assertIn("physical cores", setup.pool_workers_note(["--pool-workers", "200"], self.big)[0]) self.assertIn("one CPU socket", setup.pool_workers_note(["--pool-workers", "30"], (80, [20, 20]))[0]) if __name__ == "__main__": unittest.main()